- ENDOINJECTOR -

ENDOINJECTOR

ENDOTHERMIC / EXOTHERMIC GENERATOR CONTROL SYSTEM

The EndoInjector™ is a precision gas mixing and control system for endothermic gas generators. The system incorporates a patented fuel injection design that utilizes electronic flow measurement and precise ratio control to consistently provide the ideal gas mixture for high quality endothermic gas generation. The fuel injection design automatically delivers gas mixture on demand, providing only as much endothermic gas as your furnaces require. This design feature makes it possible to significantly reduce operating costs and eliminate gas waste. Designed to easily replace existing carburetor/pump designs, the EndoInjector™ typically pays for itself in less than one year.

 

EXOFLEX – EXOTHERMIC GAS GENERATOR

The ExoInjector™ is a precision gas mixing and control system designed specifically for exothermic gas generators. The system incorporates a patented fuel-injection design that utilizes electronic flow measurement and precise ratio control to consistently provide the ideal gas mixture for high quality exothermic gas generation.

While similar in concept, the ExoInjector™ is different from the EndoInjector™ in that it comes in modified mechanical versions to accommodate premix or nozzle mix burners with and custom HMI software that allows for predefined ratio set points for burner ignition, rich exo-, and lean exothermic gas. Further, the system can be modified to provide hydrogen content control and water vapor monitoring to ensure the furnace atmosphere is consistent and recorded for repeatable results over time.

  • Full-color touch screen
  • Integrated dew point control
  • Integrated temperature control
  • Ratio controller
  • Fuel-Injection control valve
  • Integrated paperless chart recorder (5+ yr. data storage)
  • Large turndown capability
  • Reduce operating costs
  • Touch screen control interface
  • Minimize generator setup/startup time
  • Electronic air flow meter
  • Electronic gas flow meter
  • Mixing blower
  • Relief valve
  • Air inlet filter
  • Eliminate gas waste
  • No lubrication required
  • Precision dew point control
  • Eliminate soothing of catalyst due to mistuned carburetors
Control Power 110/220 VAC @ 50/60Hz
Blower Power 230/460 VAC 3 Phase
Capacity 100-6000 CFH (Standard)
100-14,000 CFH (Extended)
Turndown 5:1 (or greater)
Min Gas Pressure +0.5 PSIG (LP Model)
+0.5 PSIG (LP Model)
Max Gas Pressure 5 PSIG All Models
Max Operating Temp 180°F
Communication Ports 232/485/Ethernet
Protocol ModbusRTU
Ports 2” NPT
(unless otherwise specified)

Gas Types Propane or Natural Gas