Carbon Potential Range- |
0.10% to 1.4% |
Output in normal heat treating- |
1000 to 1200 mV DC |
Normal sensor operating temp.- |
1400 to 1850°F ** |
Sensor cover temp limit- |
200OF max. |
Sensitivity- |
0.02 mv or .0025% C |
Accuracy- |
±0.03% C |
Stability- |
±1 mv over probe life |
Response time- |
Less than 1 second |
Impedance- |
Less than 6 K ohm |
Sensor construction- |
Stabilized zirconia solid electrolyte; patented alloy electrode |
Sensor thermal shock- |
Caution is advised, outer alloy sheath protects ceramic zirconia tube. |
Sensor Life- |
About 2 years with normal use |
Warranty- |
1 year usage, non-prorated |
Serviceability- |
No field service required, rebuildable at factory with substantial savings |
Reference air requirement- |
0.2 to 1.0 MAX SCFH filtered ambient air |
|
** minimum operating temp 1150 °F |