- Automatic flow set point calculation – calculates the required nitrogen and methanol flow rates to maintain a desired %CO at the required volume
- Customizable recipe software
- Optional integrated carbon and temperature control
- Automatic atmosphere recovery provides additional synthetic gas flow on demand, when introducing a new load into the furnace
- Integrated paperless chart recorder stores furnace temperature, %carbon, and synthetic gas flow furnace details
- Ethernet communications (Modbus RTU)
- Electronic process flow meters
- Integrated nitrogen purge
- Precision control valves
- Integrated atmosphere recovery
- Full-color touchscreen interface
AVAILABLE OPTIONS
- Carbon control (with recipes)
- Temperature control (with recipes)
- Atmosphere sensors