- FURNACEDOCTOR®-PRO -

FURNACEDOCTOR®-PRO

Portable Infrared Gas Analyzer

The FurnaceDoctor®-Pro provides portable accurate infrared measurement of CO, CO2, and CH4 and computes the % carbon, Dew-point and expected O2 probe millivolts. The unit is ideal for use in applications where a secondary reading is needed to verify in process measurement and controls for standards compliance. The FurnaceDoctor®-Pro can be used with both endothermic and exothermic atmospheres.

 

  • Accurate, affordable infrared measurement of CO, CO2, and CH4
  • Computation of % Carbon, Dew-point and expected O2 probe millivolts
  • Easy to read 7 in. LCD display with touchscreen
  • Built-in Ethernet
  • USB 2 high speed port for data logging and retrieval
  • CQI-9 compliant encrypted data logging and on-screen charts
  • Long life, quick change lithium ion battery with charge indicator (spare batteries available)
  • High-volume long-lasting filter and a secondary, self-contained, long-lasting sub-micronic filter
  • Handy Process Calculator
  • Built-in purge port satisfies safety requirements
  • Accurate calculation of atmosphere carbon potential
  • Verification of oxygen probe accuracy
  • Easy identification of furnace atmosphere problems and furnace condition
  • Evaluation of Endo and Exo generator performance, and catalyst condition
  • Optimize nitrogen methanol system performance
  • Easy retrieval of data logged gas analysis

 

Suitable for

  • Annealing
  • Austempering
  • Carbon Correction
  • Carbonitriding
  • Carburizing
  • Martempering
  • Neutral Hardening
  • Normalizing
  • Precipitation Hardening
  • Stress-Relieving
CHARACTERISTICS CO2 CO CH4
Range:
– Endothermic 0-2% 0-30% 0-10%
– Exothermic 0-20% 0-20% 0-10%
Resolution 20 ppm 0.02% 0.02%
Accuracy 1% of range 2% of range 2% of range
Operating Temperature 40-120 ºF (4-49 ºC) 40-120 ºF (4-49 ºC) 40-120 ºF (4-49 ºC)
Relative Humidity 5% – 90% non-condensing 5% – 90% non-condensing 5% – 90% non-condensing
Stability <±2% over 12 months <±2% over 12 months <±2% over 12 months
Repeatability Zero ±0.3%, Span ±1.5% Zero ±0.3%, Span ±1.5% Zero ±0.3%, Span ±1.5%
Power Requirements Analyzer: 15VDC internal battery Analyzer: 15VDC internal battery Analyzer: 15VDC internal battery
Charger: 10-220 VAC, 50-60 Hz Charger: 10-220 VAC, 50-60 Hz Charger: 10-220 VAC, 50-60 Hz