- FURNACEMETER FLOW METER -

FURNACEMETER FLOW METER

The FurnaceMeter™ represents a full range of precision flow measurement instruments utilizing our proprietary differential pressure flow measurement design proven to meet the rugged requirements of industrial heat-treatment applications. The meters utilize precision, field-proven, and certifiable differential pressure flow measurement sensors. The advanced calibration and display modules on the electronic versions include integrated flow rate alarm and flow consumption totalizing functions.The FurnaceMeter™ meets current NFPA86 guidelines for safe usage in the thermal processing industry. In addition, every FurnaceMeter™ comes complete with a 10point calibration curve traceable to a NIST transfer standard. The meters can also be field calibrated to meet CQI-9, ISO, NADCAP and QS quality audit systems.

The FurnaceMeter™ is available for either gas or liquid flow measurement. These meters can also be fitted with integrated manual flow control valves specifically designed for the gas type, inlet pressures, and scale ranges to provide precision process control for most applications.

The FurnaceMeter™ provides a retrofit footprint to most variable area meters to minimize piping changed when upgrading to differential pressure technology and in-situ calibration capabilities.

  • Meets NFPA requirements
  • Infield calibration verification
  • Integrated precise motorized control valve
  • No moving parts for the flow measurement
  • Integrated touchscreen display
  • Integrated Flow Alarm
  • Integrated Flow Totalizer
  • Calibrated in our ISO/IEC17025-2005 Calibration Lab and traceable to NIST (National Institute of Standards and Technology)
  • Multipoint calibration
Power requirements: No power required
Ambient Temperature: 32°-150°F
Max Inlet Pressure 2 PSI (Standard Model)
40 PSI (HP Model)
250 PSI (HPX Model)
Flow Accuracy: ± 4%
Repeatability: 2%
Flow Output Signal (linear): 4-20MA or RS-485
Flow Control Signal (linear): 4-20MA or RS-485
Flow Output Signal: SPDT Relay
Turndown: 15-100%

*Calibration is referenced to standard atmospheric conditions: (70°F, 14.7 PSIA)

CHARACTERISTICS STANDARD OPTION HP OPTION
Scale: To Order To Order
Turndown: 10:1 10:1
Accuracy: +/- 4% +/- 4%
Max Pressure: 5 psig 80 psig
Max Temperature: 130°F 130°F
Power: 24VDC 24VDC
Flow Signal: 4-20mA 4-20mA
Control Signal: 4-20mA 4-20mA
Flow Switch: Yes Yes
Comms Serial: RS-485 RS-485
Protocol: ModBUS-RTU ModBUS-RTU
Ethernet Port: TCP/IP TCP/IP